LUTRON RA2 IN-LINE 250W NEUTRAL DIMMER

LUT-RRK-R25NE-240

The RA2 Select family of in line dimmers and switches from Lutron can control lighting and motor loads both locally and remotely when paired with Pico wireless controls or Radio Powr Savr occupancy / vacancy sensors. This provides a system that is convenient and easy to install.

The RA2 Select family of in line dimmers and switches can control lighting and motor loads both locally and remotely when paired with Pico wireless controls or Radio Powr Savr occupancy / vacancy sensors.

This provides a system that is convenient and easy to install. RA2 Select in line load controls use Lutron patented Clear Connect RF technology which provides reliable, wireless communication with other RA2 Select devices. Each load control can be controlled individually using a Pico wireless control. Using a RA2 Select main repeater allows devices to be part of a whole house solution that can be controlled remotely from anywhere in the world.

FEATURES

  • The dimmer is trailing edge capable of 1W minimum load and up to 250W incandescent, halogen or ELV loads, and up to 1 A / 150 W of LED
  • The switch is rated for 6 AX of general-purpose lighting load and 2 A 0.5 HP of motor load
  • Allows remote control from anywhere in the space when paired with Pico wireless controls
  • When used with the RA2 Select main repeater, the load controls can be programmed via the Lutron App* to incorporate lighting scenes and schedule daily events. Also, the load controls can also be controlled from anywhere in the world
  • To maximize energy savings and provide hands-free operation, load controls can be turned on / off automatically via Radio Powr Savr occupancy /vacancy sensors
  • Small size allows for simple retrofit installation
  • Remote device association allows for inline controls to be added to a system without physically accessing the product.
     

* The Lutron app is required for setup and uses with the RA2 Select main repeater. The Lutron app is compatible with iOSR devices version 8.0 or later and AndroidT devices version 4.0 or later.

SPECIFICATIONS

Power 220 to 240VAC   50/60Hz
Typical Power Consumption Dimmer/Switch: <0.5W
Test conditions: Load and LED are off
Communication Frequency 868 MHz
Regulatory Approvals CE
Environment Ambient operating temperature: 0°C / 32°F to 40°C / 104°F 
0% to 90% humidity non condensing
Indoor use only
Communication Ra2 Select in-line load controllers communicate with the system through Radio Frequency (RF). They must be located within 18m (60ft) line of sight or 9m (30ft) through walls of a Pico wireless control, Radio Powr Savr sensor or Ra2 Select repeater. System devices operate at 868MHz.
ESD Protection Tested to withstand electrostatic discharge without damage or memory loss in accordance with IEC 61000-4-2.
Surge Protection Tested to withstand surge voltages without damage or loss of operation in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
Power Failure Power failure memory. Should power be interrupted the lamp dimmer will return to its previous state when power is restored.
Device Limits Up to 100 devices (e.g., load controls, Pico wireless controls, Radio Powr Savr sensors, shades, and repeaters) are supported per system. The main repeater counts as one device and four locations are reserved for wireless repeaters.
Note: Load controls have load type and capacity limits. For more information, see Load Type and Capacity.
Mounting Allow adequate space to ensure convective cooling of load control. Remove any insulation, heat generating equipment or obstructions within 120mm (4.75″) of the load control. For optimal RF performance, no metal or other electrically conductive material should be present within 120mm (4.75″) around the top and sides of the load control. The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures or electrical cabinets) or within metal ceilings.
Wiring RA2 Select in-line controls accept wire gauges between 0.5mm2 to 2.5mm2(20 AWG to 14 AWG).
Note: All outside wire diameters must be the same and must be between  5.2mm –  8.5mm (0.2″ –  0.3″).
Device Limits With repeater: Up to 100 devices (e.g., load controls, Pico wireless controls, Radio Powr Savr sensors, shades and repeaters) are supported per RF link. The processor counts as one device and four locations are reserved for hybrid repeaters.
Please Note: Load controls have load type and capacity limits. For more information, see Load Type and Capacity.

Share

Cables

We use cookies to improve your experience on our site. By continuing to browse our site, you agree to the use of cookies. For more information, please see our privacy policy.