LUTRON HOMEWORKS® POWPAK LOAD CONTROLLERS

LUT-POWPAK

The HomeWorks® PowPak range of load controllers from Lutron allow easy installation and integration for a variety of applications, simple switched controlled, 3rd party integration and analogue dimming. Complete with Lutron’s Clear connect RF technology.

The HomeWorks® PowPak range of load controllers from Lutron allow easy installation and integration for a variety of applications, simple switched controlled, 3rd party integration and analogue dimming. Complete with Lutron’s Clear connect RF technology.

LMK-16R-DV-B – 16A Relay Module
The RF relay module with Softswitch is a radio frequency (RF) device that uses Lutron patented Softswitch technology to control up to 16A of general purpose loads based on input from RA2 Select, RadioRA 2 and HomeWorks® systems. 

LMK-5T-DV-B – 0 to 10V Dimming Module
The RF dimming module with 0 to 10VDC control is a radio frequency (RF) control that operates 0 to 10VDC controlled fluorescent ballasts or LED drivers based on input from RA2 Select, RadioRA 2 and HomeWorks® systems. 

LMK-CCO1-24-B – Contact Closure Output Module
The RF CCO Module is a low voltage radio frequency (RF) control that provides a single dry contact closure output based on input from RadioRAR 2 and HomeWorks® QS systems. It can be powered by 24VAC of 24VDC for easy connection and integration into building management, HVAC, VAV and other 3rd party systems.


FEATURES
16A Relay Module

  • Lutron patented Softswitch technology prevents arcing of relay contacts therefore extending product lifetime
  • Various operating voltages available.
  • Capable of switching 16A of general purpose loads
  • Operates at 220 to 240VAC
  • Utilises Lutron Clear Connect RF technology on 868MHz frequency band
  • Mounts to an electrical junction box through a 21mm / 1/2″  (trade size) knockout opening
  • Complies with requirements for use in a compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3).

0 to 10V Dimming Module

  • 0 to 10VDC control link automatically sources or sinks up to 60mA to third party fixtures
  • Switches line voltage up to 5A
  • Configurable high and low end trim
  • Operates at 220 to 240VDC
  • Utilises Lutron Clear Connect RF technology on 868MHz frequency band
  • RadioRA 2 or HomeWorks® software required for system functionality
  • Mounts to an electrical junction box through a 21mm / 1/2″ knockout opening
  • Complies with requirements for use in a compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3).

Contact Closure Output Module

  • Single contact closure output including both normally open (NO) and normally closed (NC) dry contacts
  • Maintained or momentary output type
  • Operates at 24VAC or 24VDC
  • Utilises Lutron Clear Connect RF Technology on 868MHz frequency band
  • Screw tabs provided for surface mounting (recommended) or mounts to an electrical junction box through a 1/2″ or 21mm trade size knockout opening
  • Complies with requirements for use in a compartment handling environmental air (plenum) per NECR 2011 300.22(C)(3)

SPECIFICATIONS

LMK-16R-DV-B
16A Relay Module
LMK-5T-DV-B
0 to 10V Dimming Module
LMK-CCO1-24-B
Contact Closure Output Module
Compatible With RA2 Select, RadioRA 2 and HomeWorks systems RA2 Select, RadioRA 2 and HomeWorks systems RA2 Select, RadioRA 2 and HomeWorks systems
Power 120 / 277V~ 50 to 60Hz 16A 0.5 HP at 120V~ 1.5 HP at 277V~ (LMJ model)
220 to 240V~ 50 to 60Hz 16A motor:
6A (LMK , LMM , LMN, LMQ models)
120 / 277V~ 50 to 60Hz 5 A (LMJ model)
220 to 240V~ 50 to 60Hz 5A (LMK, LMM, LMN, LMQ models
IEC PELV/NECR Class 2Operating voltage:
24V~ / 24V-
Operating current, nominal: 45mA (24V~), 35mA (24V-)
Typical Power Consumption < 1.0W Typical power test conditions: all loads off, top LED on < 1.0W Typical power test conditions: all loads off < 1.0W Typical power test conditions: all loads off, CCO LED on
Contact Closure Output – – Accepts input voltages of 0 to 24V~ / 0 to 24V-
Resistive load: 1.0A (0 to 24V-), 0.5A (0 to 24V~)
Provides both normally open (NO) and normally closed (NC) dry contacts.
Maintained or momentary output type. Output is latching.
Minimum close time: 500ms
Load Maximum load: 16 A general purpose.
No minimum load requirements. Load types include, but are not limited to:
Incandescent, MLV, ELV, resistive, inductive, magnetic fluorescent and electronic fluorescent
0 to10V- Control Link Maximum Load:
60 mA, source or sink automatically configures.
Control link compatible with ANSI E1.3 2001 (R2006), IEC 60929 Annex E
Switched Maximum Load: 5 A lighting.
No minimum load requirements.
Load types include, but are not limited to: MLV, ELV, incandescent, magnetic fluorescent, electronic fluorescent and LEDs
–
Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended practice on surge voltages in low voltage AC power circuits Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991  –
Communications Operates using Clear Connect RF technology for reliable wireless communication
RF range is 9m / 30ft from repeaters
Operates using Clear Connect RF technology for reliable wireless communication
RF range is 9m / 30ft from repeaters
Recommended practice on surge voltages in low voltage AC power circuits
Operates using Clear Connect RF Technology for reliable wireless communication
RF range is 9m / 30ftfrom repeaters
Low Voltage CCO Wiring – – CCO terminals accept 20 to 16 AWG (0.5 to 1.5mm2) solid or stranded wire
Environment Ambient operating temperature: 0°C / 32°F to 55°C /131°F
Ambient operating humidity: 0% to 90% humidity, non condensing
Indoor use only
Ambient operating temperature: 0°C / 32°F to 40°C / 104°F
Ambient operating humidity: 0% to 90% humidity, non condensing
Indoor use only
Ambient operating temperature: 0°C / 32°F to 55°C /131°F
Ambient operating humidity: 0% to 90% humidity, non condensing
Indoor use only
Mounting Mounts to an electrical junction box through a 21 mm / 0.5” trade size knockout opening Mounts to an electrical junction box through a 21mm / 0.5” trade size knockout opening Screw tabs provided for surface mounting (recommended) or mounts to an electrical junction box through a 21mm / 0.5” trade size knockout opening
Dimensions Height: 87mm / 3.42”
Height incl knockout: 100mm / 3.94”
Knockout Opening: 21mm / 0.5” (trade size)
Width: 72mm / 2.82”
Depth: 32mm / 1.25”
Height: 87mm / 3.42”
Height incl knockout:100mm / 3.94”
Knockout Opening: 21mm / 0.5” 
Width: 72mm / 2.82”
Depth: 32mm/ 1.25”
Height: 87mm / 3.42”
Height incl knockout: 100mm / 3.94”
Knockout Opening: 21mm / 0.5” 
Width: 72mm / 2.82”
Depth: 32mm / 1.25”
 
Regulatory Approvals UL®, UL 2043 Plenum rated, FCC approved.
Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules:
CSA, IC, NOM, ANATEL (LMJ model)
CE, TRA, CITC (LMK model)
WPC (LMN model)
cULusR, UL 2043 Plenum rated, FCC approved.
Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules:
IC, NOM, ANATEL (LMJ model)
CE, TRA, CITC (LMK model)
WPC (LMN model)
ULR, UL 2043 Plenum rated, FCC approved.
Complies with the limits for a Class B device, pursuant to Part 15 of FCC rules, IC, (LMJ model only), CE, TRA, CITC (LMK model

 

Share

We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners. View more
Cookies settings
Accept
Do not accept
Privacy & Cookie policy
Privacy & Cookies policy
Cookie name Active

Who we are

Suggested text: Our website address is: https://wave-es.com/new.

Comments

Suggested text: When visitors leave comments on the site we collect the data shown in the comments form, and also the visitor’s IP address and browser user agent string to help spam detection. An anonymized string created from your email address (also called a hash) may be provided to the Gravatar service to see if you are using it. The Gravatar service privacy policy is available here: https://automattic.com/privacy/. After approval of your comment, your profile picture is visible to the public in the context of your comment.

Media

Suggested text: If you upload images to the website, you should avoid uploading images with embedded location data (EXIF GPS) included. Visitors to the website can download and extract any location data from images on the website.

Cookies

Suggested text: If you leave a comment on our site you may opt-in to saving your name, email address and website in cookies. These are for your convenience so that you do not have to fill in your details again when you leave another comment. These cookies will last for one year. If you visit our login page, we will set a temporary cookie to determine if your browser accepts cookies. This cookie contains no personal data and is discarded when you close your browser. When you log in, we will also set up several cookies to save your login information and your screen display choices. Login cookies last for two days, and screen options cookies last for a year. If you select "Remember Me", your login will persist for two weeks. If you log out of your account, the login cookies will be removed. If you edit or publish an article, an additional cookie will be saved in your browser. This cookie includes no personal data and simply indicates the post ID of the article you just edited. It expires after 1 day.

Embedded content from other websites

Suggested text: Articles on this site may include embedded content (e.g. videos, images, articles, etc.). Embedded content from other websites behaves in the exact same way as if the visitor has visited the other website. These websites may collect data about you, use cookies, embed additional third-party tracking, and monitor your interaction with that embedded content, including tracking your interaction with the embedded content if you have an account and are logged in to that website.

Who we share your data with

Suggested text: If you request a password reset, your IP address will be included in the reset email.

How long we retain your data

Suggested text: If you leave a comment, the comment and its metadata are retained indefinitely. This is so we can recognize and approve any follow-up comments automatically instead of holding them in a moderation queue. For users that register on our website (if any), we also store the personal information they provide in their user profile. All users can see, edit, or delete their personal information at any time (except they cannot change their username). Website administrators can also see and edit that information.

What rights you have over your data

Suggested text: If you have an account on this site, or have left comments, you can request to receive an exported file of the personal data we hold about you, including any data you have provided to us. You can also request that we erase any personal data we hold about you. This does not include any data we are obliged to keep for administrative, legal, or security purposes.

Where your data is sent

Suggested text: Visitor comments may be checked through an automated spam detection service.
Decline All
Save settings Accept All
Cookies settings