LUT-QSE-IO
The HomeWorks® QSE-IO contact closure interface from Lutron provides integration with third party equipment requiring contact closure input and output including occupancy and vacancy sensors, motorised projection screens, skylights and window shades. It also includes an interface with AV equipment, security systems, movable partition walls and time clocks. One QSE-IO interface provides 5 dry contact closure outputs and 5 inputs.
The HomeWorks® QSE-IO contact closure interface from Lutron provides integration with third party equipment requiring contact closure input and output including occupancy and vacancy sensors, motorised projection screens, skylights and window shades.
It also includes an interface with AV equipment, security systems, movable partition walls and time clocks. One QSE-IO interface provides 5 dry contact closure outputs and 5 inputs.
It may be programmed to control or be controlled on a QS system.
For complete functionality, programming instructions and detailed DIP switch settings, please refer to the QSE-IO Programming Guide in the downloads section.
FEATURES
SPECIFICATIONS
Regulatory Approvals | UL® listed, cUL® listed, CE compliant |
Power | SELV / PELV / NEC® Class 2 Operating voltage: 24 to 36VDC 100mA |
QS Link Limits | The QS wired communications link is limited to 100 devices and 100 zones. Each QSE-IO control interface counts as 1 device and 5 zones
Each QSE-IO control interface consumes 3 Power Draw Units (PDU) on the QS link. Please refer to the QS Link Power Draw Units Specification Submittal (P/N 369405) at www.lutron.com for more information The maximum wiring length for the QS link is 610m / 2000ft |
Environment | Operating temperature: 0°C / 32°F to 40°C / 104°F Relative humidity less than 90% non condensing Indoor use only Unit generates heat: maximum 8 BTU/hr |
Functionality and Operating Modes | Using the inputs and contact closures in other equipment can operate control units to:
Using the outputs, scene and/or zone changes in control units can: Trigger outputs to control other equipment Using the inputs and contact closures in other equipment can operate Sivoia® QS window treatments to: Open or close Using the outputs and key presses on QS window treatment keypads or GRAFIK Eye® QS window treatment buttons can:
For a full list of functionality and operating modes, please see the Operating Modes and Dipswitch Settings table on Pages 8 and 9 |
Requirements | QS Link Power Supply, such as: Grafik Eye® QS QS Link power supply, such as the QSPS-P1-1-50 Energi Saver NodeTM QS Quantum® light management hub QS Communication Link (SELV / PELV/NEC® Class 2) (see QS Link Wire Sizes table) |
Five Input Terminals | Accept maintained inputs and momentary inputs with 40msec minimum pulse times Off-state leakage current must be less than 100μA Open circuit voltage: 24VDC maximum Inputs must be dry contact closure, solid state, open collector or active-low (NPN)/active high (PNP) output Open collector NPN or active-low on-state voltage must be less than 2VDC and sink 3.0mA Open collector PNP or active high on state voltage must be greater than 12VDC and source 3.0mA |
Five Output Terminals | Provide selectable maintained or momentary (1/4 second) outputs (SELV/PELV/NEC® Class 2 rated only)
The QSE-IO is not rated to control unclamped inductive loads. Inductive loads include, but are not limited to relays, solenoids and motors. To control these types of equipment, a fly back diode must be used (DC voltages only). See “Terminal Locations” Output relays are non latching (if relays are closed and power is lost, relays will open) |
Status LEDs | Five Status LEDs light when associated output is active (on) |