LUTRON HOMEWORKS 0 TO 10V CONTROLS POWER MODULE

LUT-LQSE-4T10-D

Lutron’s HomeWorks 0 to 10V Power Module is a 4 zone power module designed to control 0 to 10V dimmable lighting loads as well as switching lighting loads. It includes QS link for seamless connection to a HomeWorks QS system.

Lutron’s HomeWorks 0 to 10V Power Module is a 4 zone power module designed to control 0 to 10V dimmable lighting loads as well as switching lighting loads.

It includes QS link for seamless connection to a HomeWorks QS system.

These power module units can be used in a HomeWorks QS system to control and manage light in an entire home or building.

FEATURES

  • Rated for lighting loads as defined by IEC/EN 60669 as well as INC, MLV, and ELV
  • LEDs on the module provide diagnostic information
  • Buttons on the module provide override control
  • Manual Override Contact Closure Input (CCI)
  • Programmable Contact Closure Output (CCO)
  • Power failure memory automatically returns the outputs to the levels they were set to prior to a power outage

SPECIFICATIONS

Power 230 V~ 50/60 Hz
Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6000 V~ and current surges of up to 3000 A. 
Current draw: 50mA max
Standby power: 1 W
BTUs/hour when fully loaded: 4
Regulatory Approvals IEC/EN 60669-2-1,  EN50428
Lutron® Quality Systems registered to ISO 9001.2008
CE marked
C-Tick
Environment Ambient Temperature Operating Range (inside mounting panel): 0ºC to 40ºC
Calibration point maximum: 65ºC
Relative humidity: less than 90% noncondensing
For indoor use only.
Output Zone Ratings Each zone is rated at 10 A for switching. Rated for resistive, inductive or capacitive lighting loads as defined by IEC/EN 60669-2-1
Switched outputs utilize latching relays to maintain relay state if control power is lost.
0 to 10V rated for 50mA maximum output, source or sink per zone.
Programming and Compatibility Requirements Setup and programming of the Switching Module is done through the HomeWorks QS programming software
HomeWorks QS software version 3.0 or higher required
QS Link Limits A QS link in a HomeWorks QS system can have up to 512 zones (outputs) and 100 devices (required HomeWorks QS processor counts as 1 device on the QS link).
Each Switching Module counts as one device toward the 100 device limit, and 4 zones toward the 512 zone limit.
Terminals Torque – 0.6Nm (5in-lbs)
Power terminals

0.5mm2 to 6mm2 

0-10Vterminals

0,5mm2 to 2,5mm2

Data terminal

0.5mm2 to 2.5mm2 

0.5mm2 to 1mm2 

Mounting Please consult the product specification sheet for mounting details.
Dimension Width: 162mm / 6.38″
Height: 90mm / 3.54″
Depth: 61mm / 2.4″


Share

Cables

We use cookies to improve your experience on our site. By continuing to browse our site, you agree to the use of cookies. For more information, please see our privacy policy.